Analysis of Welding Results on Stringer Tertiary Screen Using NDT Magnetic Particle Test Method at PT. PAL Indonesia

Budi SetiyanaMechanical Engineering Department, Faculty of Engineering, Diponegoro University, Jl. Prof. H. Soedarto, SH, Tembalang-Semarang 50275, IndonesiaMoh. FaojiMechanical Engineering Department, Faculty of Engineering, Diponegoro University, Jl. Prof. H. Soedarto, SH, Tembalang-Semarang 50275, IndonesiaMuchammadMechanical Engineering Department, Faculty of Engineering, Diponegoro University, Jl. Prof. H. Soedarto, SH, Tembalang-Semarang 50275, Indonesia

Vol 7 No 11 (2023): Volume 7, Issue 11, November 2023 | Pages: 1-7

International Research Journal of Innovations in Engineering and Technology

OPEN ACCESS | Research Article | Published Date: 03-11-2023

doi Logo doi.org/10.47001/IRJIET/2023.711001

Abstract

Welding is the process of joining materials in the manufacturing industry. To maintain the quality of welding results in accordance with established standards, it is necessary to inspect or inspect the product. To find out whether or not there are defects in the product before the next process is carried out, or before the product is marketed, an inspection is usually carried out using a non-destructive testing (NDT) method, namely testing materials without damaging the material being tested. Several types of non-destructive testing, namely, visual checking, penetrant test, radiographic test and magnetic particle test. This article discusses about the welding analysis of stringer tertiary screen at PT PAL Indonesia. To check whether there are defects in the welded joints in the stringer tertiary screen, a visual check and magnetic particle test have been carried out. Based on interpretation using ASME section IX, the test results show that there are several defects such as spatter on the base metal and wormholes which are unacceptable. The finding of this defect has been followed up with re-welding repairs as recommended. For spatter defects, repairs are carried out with the help of an air chipping hammer which functions to clean the spatter from the base metal, then for wormhole defects repairs are carried out by dismantling the weld and re-welding. The results of repeated visual checks and magnetic particle tests after repair showed that the defects had been successfully eliminated. Thus, the welding results on the stringer tertiary screen are acceptable.

Keywords

Welding, Magnetic Particle Test, ASME


Citation of this Article

Budi Setiyana, Moh. Faoji, Muchammad, “Analysis of Welding Results on Stringer Tertiary Screen Using NDT Magnetic Particle Test Method at PT. PAL Indonesia” Published in International Research Journal of Innovations in Engineering and Technology - IRJIET, Volume 7, Issue 11, pp 1-7, November 2023. Article DOI https://doi.org/10.47001/IRJIET/2023.711001

References
  1. Aqdar Fitrah, M. and Balfas, M., (no date).Analysis of Welding Defects Resulting from Welding a Combination, of GTAW and SMAW 6G Position on SA 106 Grade B Pipe.
  2. Bakhori, A., 2021.Analysis of Welding Defects in Low Carbon Steel on the Effect of Welding Heat Input, Semnastek Uisu, pp. 0–5.
  3. Hari Moektiwibowo, G.S. and Wijayanto B.A., 2000. Analysis of Factors Causing Welding Defects, pp. 109–122.
  4. Nofri, M., Taryanaand Acang, 2017. Analysis of the Mechanical Properties of SKD 61 Steel and ST41 Steel was carried out by Hardening with Temperature Variations, pp. 189-199.
  5. Rohimudin, R. Anugrah Dwiputra, G. and Supriyadi, S., 2016. Defect Analysis on Steel Construction Plate Welding Results Using the Six Sigma Method,pp. 1-10.
  6. Santoso, A., Probadi, J. and Raharja, S., 2022. Detection of Welding Defects in Low Carbon Steel using the Transfer Function for Non-Destructive Test (NDT), pp. 105-115.
  7. Sulaiman, F., Jannifar and Bukhari, 2020. Analysis of SMAW welding defects on ST 45 material using magnetic particle tests and ultrasonic tests, pp. 26-31.